Technical data applicable to certified doors
Resistance to wind load on the outside of a building applicable to doors,
classification to EN 12424
Element thickness, d = 39 mm |
||||
Span width
[m] |
Door element without window + without reinf. prof. |
Door element without window + with small reinf. prof. |
Door element without window + with large reinf. prof. |
Door element with 3 windows + without reinf. prof. |
2.5 |
Class 5 |
|||
3.5 |
Class 3 |
|||
4.0 |
Class 3 |
Class 2 |
||
4.5 |
||||
5.0 |
||||
5.5 |
||||
6.0 |
Class 2 |
|||
6.5 |
||||
7.0 |
||||
7.5 |
Class 2 |
|||
8.0 |
||||
8.5 |
Class 3 |
|||
Wind protection classes
Class |
Class 1 |
Class 2 |
Class 3 |
Class 4 |
Class 5 |
| Load incl.
25% safety fact. |
300 Pa |
450 Pa |
700 Pa |
1000 Pa |
> 1000 Pa |
Air permeability to EN 12 426
Span [m] |
2.5 |
3.0 |
3.5 |
≥ 4 |
| Door element without reinf. prof. |
Class 3 |
Class 3 |
Class 3 |
Class 4 |
Resistance to water ingressto EN 12 425
Span [m] |
4.0 |
| Door element without reinf. prof. |
Class 3 |
Heat transfer coefficient to EN 12 428
Span [m] |
Door el. without window |
Door el. with window |
8.5 |
U-value [W/m²K] |
U-value [W/m²K] |
1.0 |
1.0 |